A1 Fireproofing and Specialty Coatings is an intumescent fireproofing contractor serving Los Angeles County from our base in Huntington Beach. Intumescent is the thin-film option: it goes on exposed structural steel that the architect wants to leave visible, and it still delivers the hourly rating on the drawings. In Los Angeles that is a lot of steel: open-ceiling tenant improvements Downtown and on the Westside, lobbies and canopies on mid-rise office and mixed-use buildings, exposed roof structure on retail and restaurant TIs, and stairs and mezzanines in creative office conversions. If your set calls for a thin-film fire-resistive coating on exposed steel, send it to us and we will give you a real number.
What we do as an intumescent fireproofing contractor in Los Angeles
Intumescent coatings look like a heavy film finish at room temperature. In a fire they swell to many times their thickness and form a char that insulates the steel, which is how a coating a few millimeters thick carries a one- or two-hour rating. It only works if it is applied to the right film thickness, over the right primer, with a compatible topcoat.
On a Los Angeles job that means:
- Reading the UL design and the fireproofing schedule to get the required dry film thickness for each member size and rating
- Confirming the primer on the steel is one the manufacturer lists as compatible, or specifying the one that needs to go on
- Surface prep, masking, and building the coating up in measured coats
- Taking and recording dry film thickness readings so the special inspector has numbers, not guesses
- Coming back to touch up after other trades have bolted, welded or hung from the steel
We install Carboline, Isolatek CAFCO and Hilti intumescent systems, matched to the spec, the rating and interior or exterior exposure. Our intumescent fireproofing page covers the products in more detail.
How we price it off your drawings
Intumescent is priced by the member, not by the square foot of floor. Send us the structural drawings, the architectural sheets showing which steel is exposed and rated, and the intumescent spec section. From those we work out the surface area of each member, the thickness per the UL design and the number of coats, and give you a bid that covers primer coordination, material, labor, masking and documentation.
Things that move the price on Los Angeles intumescent work:
- Rating and member size. A two-hour rating on a light column takes far more film than a one-hour rating on a heavy beam.
- Primer condition. Shop primer that is not on the manufacturer’s compatibility list has to be dealt with before we start.
- Finish expectations. Architectural steel in a lobby gets a different level of finish than a back-of-house mezzanine.
- Exterior exposure. Canopies and exterior steel need an exterior-rated system and a weathering topcoat.
- Access. A 40-foot atrium from lifts is a different job than a stair stringer.
If something on the set is unclear, we ask before we bid rather than carry an assumption into a change order.
What keeps the schedule moving
Intumescent goes on late, after the steel is up and usually after the roof is on, and it needs clean, dry conditions for the coats to cure right. Here is what we need from the general contractor on a Los Angeles project:
- Steel erected, welded and cleaned, with any shop primer identified on the submittals
- Enclosure and temperature control where the manufacturer requires it, since cure times stretch in a cold, open building
- A sequence that keeps drywall dust, welding splatter and other trades’ overspray off the steel between coats
- Agreement up front on who the special inspector is and when film thickness gets checked
- A plan for the finish topcoat, since it is often a separate scope on the schedule
Exposed steel in Los Angeles is normally subject to deputy inspection, and intumescent inspections focus on film thickness and primer compatibility. We keep our readings in a format the inspector can sign off on without a second visit.
Areas we cover near Los Angeles
We take intumescent fireproofing work throughout Los Angeles County, including Downtown Los Angeles, Hollywood, Century City, Santa Monica, Culver City, Playa Vista, El Segundo, Inglewood, Long Beach, Torrance, Burbank, Glendale, Pasadena, Sherman Oaks, Woodland Hills, Santa Clarita, Pomona and Whittier. For the concealed-steel side of the same jobs, see our spray fireproofing in Los Angeles page.
Get a number on your Los Angeles intumescent scope
Send your drawings to info@A1fireproofingandspecialtycoatings.com or call us at (562) 475-2757. We will look at the set and get a bid back to you. A1 Fireproofing and Specialty Coatings is based in Huntington Beach and works commercial fireproofing across Los Angeles, Orange County, the Inland Empire and San Diego.